Bitdefender alerts regarding PAExec used by Medulla
Applies to: Medulla / Bitdefender GravityZone
Version: Medulla 5.6.x / GravityZone depending on available features
Environment: Windows / Medulla On-Premise or SaaS
Category: Security / EDR / Antivirus / Remote Execution
Affected component: PAExec
This FAQ explains why Bitdefender GravityZone may detect or block certain operations performed by Medulla using PAExec, and how to diagnose the relevant events.
It also outlines the exclusion options provided by Bitdefender GravityZone to resolve any compatibility issues while maintaining the security level of managed workstations.
Important:
Security exclusions should only be implemented when an actual block has been identified and the legitimate source of the execution has been verified.
Any exclusion must be limited to the strictly necessary scope, validated by the security team, and regularly reevaluated.
1. Background: why does Medulla use PAExec?
Medulla uses PAExec, a remote execution tool compatible with PsExec’s operating principles, to perform certain administrative tasks on Windows workstations.
Depending on the features and use cases, this mechanism can be used for:
- Application deployment.
- Executing commands or scripts.
- Launching certain actions from the application Kiosk.
- Maintenance and administrative tasks.
- Certain automated actions requiring elevated privileges.
In Medulla, this mechanism is notably used by the following component:
scheduling_launch_kiosk.py
PAExec is a legitimate administration tool. However, the techniques it employs can also be exploited by attackers to execute commands remotely or perform lateral movement within a network.
Security solutions such as Bitdefender GravityZone can therefore monitor or block certain behaviors associated with PAExec.
Note:
A PAExec detection does not necessarily mean that the workstation is compromised.
However, it must be verified to confirm that the execution is indeed an authorized Medulla operation.
2. Why can Bitdefender detect PAExec?
PAExec uses a mechanism that relies, in particular, on the creation and execution of a temporary Windows service.
In the scenario described here, its operation may involve the following steps:
- Medulla triggers an operation requiring PAExec.
- The PAExec binary is used to prepare for execution.
- A temporary copy of the program is created on the affected workstation.
- A temporary Windows service is installed.
- The service performs the requested action with the necessary privileges.
- The service and the temporary file are normally deleted at the end of the operation.
These operations may trigger antivirus or behavioral detection mechanisms.
Bitdefender may analyze, in particular:
- The creation of an executable file.
- The launch of a process.
- The creation of a Windows service.
- Operations performed with elevated privileges.
- Behaviors that may indicate an attempt at remote execution.
Caution:
The observed events must be cross-referenced with the Medulla logs and the administrator’s action history.
Do not automatically assume that every PAExec detection is a false positive.
3. Which PAExec files are used by Medulla?
Source binary
The PAExec binary installed with the Medulla agent is typically located in:
C:\Program Files\Medulla\bin\paexec.exe
Temporary copy
During certain executions, PAExec may create a temporary copy in the Windows directory.
The file name may be dynamic:
C:\Windows\PAExec-<PID>-<ComputerName>.exe
Example:
C:\Windows\PAExec-2124-CSE-SDN-ALV-02.exe
The exact name depends on the execution and the environment.
Note:
Bitdefender may detect the source binary or its temporary copy.
Therefore, excluding only the paexec.exe file may not be sufficient if the block applies to the temporary file.
4. Why does PAExec run under NT AUTHORITY\SYSTEM?
In the described operation, PAExec uses a temporary Windows service.
This service can be run under the following account:
NT AUTHORITY\SYSTEM
It can also be launched with the argument:
-service
This behavior allows the service to have the privileges required for certain administrative operations.
Expected behavior:
The use of the SYSTEM account and the -service argument is consistent with how PAExec operates in this scenario.
However, these elements must be verified in the context of execution.
5. What Windows events can be observed?
Operations performed by PAExec can generate several Windows events, depending on the audit settings enabled on the workstation.
| ID | Log | Description | Presence |
|---|---|---|---|
| 7045 | System | Installation of a new Windows service. | Possible |
| 7036 | System | Change in the status of a Windows service. | Possible |
| 5145 | Security | Verifying access to a shared object on the network. | Depending on audit settings |
| 4648 | Security | Logging in with explicit credentials. | Depending on the scenario |
| 4688 | Security | Creation of a new process. | If audit is enabled |
Events related to administrative shares or named pipes may also be observed when these mechanisms are used.
Examples of pipes associated with PAExec operation:
*-stdin
*-stdout
*-stderr
Note:
The presence of these events depends on the Windows configuration, audit policies, and the execution scenario.
They are not systematically generated or logged on all workstations.
6. Which Bitdefender modules may be involved?
Bitdefender GravityZone has several protection mechanisms that may be triggered during a PAExec execution.
Antimalware – On-access
This module scans files when they are accessed, including when they are created, copied, opened, or executed.
It can intervene when PAExec creates or executes its temporary copy.
Antimalware – On-demand
This module performs on-demand or scheduled scans.
It can detect a PAExec file present on the disk during a scan.
Advanced Threat Control – ATC/IDS
This mechanism monitors behavior that may indicate malicious activity.
It can intervene when multiple operations considered sensitive are performed during a single execution.
Ransomware Mitigation
This module helps detect and mitigate the consequences of certain ransomware-type activities.
Its potential involvement must be confirmed in the detection details.
Other protection modules
Depending on the license, version, and configuration of GravityZone, other mechanisms may be available, including:
- Advanced Anti-Exploit.
- Process Inspection.
- LSASS Protection.
- EDR/XDR detection mechanisms.
Important:
It is essential to identify the module that actually triggered the block before creating an exclusion.
An Antimalware exclusion does not necessarily guarantee the removal of a detection from another module.
7. Where can I view PAExec detections in GravityZone?
Log in to the GravityZone Control Center console with an account that has the necessary permissions.
Depending on your version and the modules you have subscribed to, detections can be viewed in the sections related to incidents, threats, reports, or workstation activity.
Look for the following information in particular:
- The name of the affected workstation.
- The date and time of the detection.
- The path to the detected file.
- The name of the threat or detection.
- The protection module involved.
- The action taken by Bitdefender: blocking, quarantining, or other remediation.
- The affected process and, when available, process lineage information.
You can search for the following paths:
C:\Program Files\Medulla\bin\paexec.exe
C:\Windows\PAExec-*.exe
Then compare the detection time with the history of operations performed in Medulla.
Best practice:
Before making any changes to the security policy, save the detection information so you can accurately verify the effectiveness of any exclusions.
8. Where can exclusions be configured in Bitdefender GravityZone?
Bitdefender GravityZone allows you to manage exclusions from security policies and, depending on the console version, from centralized configuration profiles.
Method 1 – Exclusions in a policy
- Log in to the GravityZone Control Center.
- Open the Policies menu.
- Select an existing policy or create a dedicated one.
- Go to Antimalware > Exclusions.
- Enable exclusions in the policy if necessary.
- Add rules appropriate for the identified issue.
- Save the policy.
- Verify that it is assigned to the affected workstations.
Method 2 – Centralized exclusions
Versions of GravityZone that include configuration profiles allow you to create exclusions that can be reused across multiple policies.
- Open Policies > Configuration profiles.
- Go to the Exclusions section.
- Create a list of exclusions or select an existing list.
- Add the necessary rules.
- Associate the list with the relevant policy.
- Verify that this policy is applied to Medulla workstations.
Note:
The exact labels and menu layout may vary depending on the version of GravityZone and the features available in your environment.
9. What types of exclusions are available in GravityZone?
GravityZone documents several types of exclusions.
| Type | How it works | Relevance to PAExec |
|---|---|---|
| File | Excludes a specific file. | Targeted exclusion of the source binary or temporary copy. |
| Folder | Excludes the contents of a folder and its subfolders. | Should be avoided as a first resort due to its broader scope. |
| Extension | Excludes files with a given file extension. | Not recommended for PAExec. |
| Process | Excludes objects accessed by the specified process, based on the selected modules. | Evaluate with caution, as the scope may extend beyond the binary itself. |
| File Hash | Excludes a file identified by its SHA256 hash. | Allows for precise identification of a specific version of the binary. |
| Certificate Hash | Excludes applications that match a certificate hash. | Only if an appropriate certificate is present and verified. |
| Threat Name | Excludes a detection identified by its name. | Use with extreme caution. |
| Command Line | Excludes a specified command line. | May allow for more precise targeting in certain scenarios. |
The available exclusion types and the modules to which they can be applied depend on the version and configuration of GravityZone.
Caution:
A Process exclusion is not the same as a File exclusion.
Depending on the module in question, a process exclusion may also affect the objects accessed by that process.
10. How do I exclude the PAExec source binary?
When the detection directly involves the binary installed with Medulla, a targeted File exclusion can be considered.
Path in question
C:\Program Files\Medulla\bin\paexec.exe
Procedure
- Open the exclusion list for the relevant policy or profile.
- Add a new exclusion.
- Select the File type.
- Specify the full path to the PAExec binary.
- Select only the module(s) that caused the block, if the interface allows it.
- Add a justification to the rule.
- Save the changes.
- Verify that they are applied on the pilot workstation.
Example of a justification:
Medulla - PAExec
Targeted exclusion of the source binary
Reason: compatibility with Medulla administration operations
Scope: Medulla pilot workstations
Note:
This exclusion applies to the source binary.
It does not necessarily cover the temporary copy generated during certain executions.
11. How do I exclude the PAExec temporary copy?
When Bitdefender blocks the PAExec temporary copy, the detected path may follow this format:
C:\Windows\PAExec-<PID>-<ComputerName>.exe
Example:
C:\Windows\PAExec-2124-CSE-SDN-ALV-02.exe
Since the file name changes from one execution to the next, an exclusion based solely on the full name of a temporary file can quickly become ineffective.
Exclusion by path with wildcards
GravityZone documents support for wildcards in exclusion paths.
A File rule can therefore be considered with the following path:
C:\Windows\PAExec-*.exe
This expression targets executable files located directly in C:\Windows\ whose names begin with PAExec-.
Procedure
- Identify the Bitdefender module that blocked the file.
- Open the exclusions settings.
- Add a File rule.
- Enter the path using the wildcard character.
- Limit the exclusion to the relevant module whenever possible.
- Apply the rule only to pilot workstations.
- Restart a Medulla operation that was previously blocked.
- Verify the result in Medulla and GravityZone.
Security risk:
This exclusion relies on a predictable filename. Malicious software could use a filename following the same pattern.
Therefore, it should not be considered a guarantee that the file is the Medulla binary.
Its use requires security validation and appropriate monitoring.
12. Which wildcards are supported by GravityZone?
The Bitdefender documentation describes the following wildcards for exclusion paths:
| Character | Meaning |
|---|---|
* |
Matches zero or more characters. |
? |
Matches exactly one character. |
** |
Allows matching across multiple path levels according to the rules documented for Windows. |
Examples documented by Bitdefender:
C:\Test\*.png
C:\Test\*
**\file.txt
For PAExec, the pattern under consideration is:
C:\Windows\PAExec-*.exe
Caution:
Avoid overly broad expressions, especially those using ** without path restrictions.
Misuse of wildcards can significantly expand the scope of an exclusion.
13. Can Windows system variables be used?
Yes.
GravityZone documents the use of system variables in exclusion paths.
For example:
%ProgramFiles%
%WINDIR%
These variables allow you to tailor certain exclusions to the actual configuration of the workstation.
Example for the PAExec temporary copy
When the exclusion field accepts this syntax:
%WINDIR%\PAExec-*.exe
This format may be preferable to a fixed path when the Windows directory is not always located on drive C:.
Recommendation:
Use system variables whenever their use is compatible with the rule you’ve created, and verify the result on a pilot workstation.
14. Can PAExec be excluded based on its SHA256 hash?
Yes.
Bitdefender GravityZone documents File Hash exclusions using the SHA256 algorithm.
This method allows you to precisely identify specific binary content.
Retrieve the SHA256 hash
On a workstation running the Medulla agent, open PowerShell and run:
Get-FileHash "C:\Program Files\Medulla\bin\paexec.exe" -Algorithm SHA256
Example output:
Algorithm : SHA256
Hash : <SHA256_HASH>
Path : C:\Program Files\Medulla\bin\paexec.exe
Create the exclusion
- Open the GravityZone exclusions configuration.
- Add a new exclusion.
- Select File Hash.
- Enter the SHA256 hash of the verified file.
- Select the relevant module(s).
- Save the rule.
- Apply it to the pilot workstations.
- Verify Medulla’s behavior.
Advantage:
An exclusion based on a hash is more precise than one based solely on a filename.
It allows you to identify a specific version of the PAExec binary.
Limitations:
A different SHA256 hash requires a re-evaluation of the rule.
You must also verify that the temporary copy matches the same binary content.
Bitdefender also notes that hash-based exclusions can result in additional CPU usage due to hash calculation.
15. How do I verify the hash of the temporary copy?
When a temporary PAExec copy is present on the workstation, its hash can be compared to that of the source binary.
In PowerShell:
Get-FileHash "C:\Program Files\Medulla\bin\paexec.exe" -Algorithm SHA256
Then, by adjusting the name of the temporary file:
Get-FileHash "C:\Windows\PAExec-2124-CSE-SDN-ALV-02.exe" -Algorithm SHA256
If the two hashes are identical, the two files have the same binary content.
Note:
The temporary file may be deleted very quickly after execution.
Therefore, it is not always possible to retrieve its hash afterward.
Caution:
Do not disable the workstation’s security protections simply to keep a copy of the file.
If the file is blocked or quarantined, follow the analysis and collection procedures approved by your security team.
16. Does the hash change after a Medulla update?
It may change.
If the PAExec binary is replaced with a different version during an update, its SHA256 hash will be different.
It is recommended to verify the hash after:
- A major Medulla update.
- A Windows agent update.
- A replacement of the PAExec binary.
- A new detection related to PAExec.
Note:
A Medulla update does not necessarily modify the PAExec binary.
The hash changes only if the file’s contents are modified.
17. Can PAExec be excluded by process?
Yes, GravityZone offers Process type exclusions.
However, this method should be distinguished from a file exclusion.
According to Bitdefender’s documentation, a process exclusion may affect the objects accessed by the excluded process, depending on the selected protection modules.
The path to the source process may be:
C:\Program Files\Medulla\bin\paexec.exe
A process exclusion can therefore have a broader scope than an exclusion targeting only the executable file.
Recommendation:
For a block that affects only the PAExec file, first consider a File or File Hash exclusion.
Use a Process exclusion only if the responsible module and the behavior to be excluded have been clearly identified.
18. Can a PAExec command line be excluded?
Yes, GravityZone documents Command Line exclusions for Windows.
This option may be useful when the block applies to a specific command rather than the file itself.
In the PAExec scenario described, one argument that can be observed is:
-service
However, this argument alone does not provide a sufficiently reliable way to identify a Medulla operation.
Any command-line exclusion must therefore be based on the complete command actually observed in the security events.
Caution:
Do not add a general exclusion based solely on the -service argument.
Such a rule could match other programs or execution scenarios.
19. Which exclusion should be prioritized for PAExec?
The choice depends on the Bitdefender module that triggered the block and the available information.
| Situation | Exclusion to consider | Precaution |
|---|---|---|
| Blocking of the source binary | File on the exact path | Limit to the responsible module. |
| Blocking a known version of the binary | File Hash SHA256 | Verify the hash and its stability. |
| Blocking of a temporary copy with a dynamic name | File with the pattern PAExec-*.exe | Risk of name spoofing; security validation required. |
| ATC/IDS behavioral detection | Targeted exclusion tailored to the module | First analyze the events and the actual scope of the exclusion. |
| Blocking of a specific command | Command Line, if applicable | Use the complete, verified command. |
| Multiple Medulla components blocked | Analyze on a case-by-case basis | Do not automatically exclude the entire Medulla folder. |
Recommended approach:
Start by precisely identifying the block, then select the most restrictive rule compatible with the affected module.
Validate the result on a pilot workstation before any wider deployment.
20. Should the entire Medulla directory be excluded?
No, not automatically.
The main directory of the Medulla agent is generally:
C:\Program Files\Medulla\
GravityZone allows you to create Folder type exclusions.
However, a folder exclusion may cover all files and processes in the directory and its subdirectories, depending on the modules involved.
It is therefore broader in scope than a targeted exclusion of just the PAExec binary.
It is best to start by examining the following paths:
C:\Program Files\Medulla\bin\paexec.exe
C:\Windows\PAExec-*.exe
Important:
Excluding the entire Medulla directory should only be considered after analyzing several confirmed incompatibilities and receiving approval from the security team.
It should not be the default configuration.
21. Which exclusions should be avoided?
The following exclusions are strongly discouraged:
C:\Windows\
C:\Program Files\
C:\
*.exe
**\*.exe
These expressions may exclude a very large number of files or processes.
They may significantly reduce the effectiveness of antivirus and behavioral protection.
It is also not recommended to globally exclude:
- All processes running under SYSTEM.
- All Windows services.
- All remote administration tools.
- All detections associated with PsExec or PAExec.
- An entire threat category without prior analysis.
Caution:
Do not globally disable the Antimalware, ATC/IDS, or Ransomware Mitigation modules to resolve a PAExec compatibility issue.
22. How do I apply a dedicated policy to Medulla workstations?
It is recommended to create a specific policy for workstations on which a PAExec incompatibility has been confirmed.
Create or customize a policy
- Log in to GravityZone Control Center.
- Open Policies.
- Create a new policy or clone an existing one.
- Add only the necessary exclusions.
- Save the policy.
Assign the policy
- Open the Network section.
- Select the relevant pilot workstations.
- Open the Actions menu.
- Select Assign policy.
- Select the appropriate policy.
- Confirm the assignment.
Then verify that the workstations are actually using the expected policy.
Note:
Centralized exclusions can be reused in multiple policies when the corresponding configuration profiles are available in GravityZone.
23. How do I verify that the exclusion is working?
After applying the policy, perform the checks on a pilot workstation.
Step 1 – Check the Bitdefender status
Confirm that:
- The Bitdefender Endpoint Security Tools agent is active.
- The expected policy is applied.
- Protections not affected by the exclusion remain enabled.
Step 2 – Test a Medulla operation
From Medulla, perform an operation corresponding to the scenario that was previously blocked.
Depending on your environment, this may involve:
- An application deployment.
- A script execution.
- A maintenance action.
- An operation launched from the application Kiosk.
Step 3 – Verify the result in Medulla
Check:
- Whether the operation has started.
- That it is running on the workstation.
- Its final result.
- Any errors logged in the Medulla history or logs.
Step 4 – Check GravityZone
Verify that:
- The relevant PAExec file is no longer blocked in the tested scenario.
- No new quarantines are preventing the operation.
- The module that previously caused the block no longer interrupts legitimate execution.
- The other protections remain operational.
Validation:
The exclusion can be considered functionally effective when the previously blocked Medulla operation completes successfully and the initial cause of the block no longer recurs.
This functional validation does not replace the security assessment of the exclusion.
24. What should you do if PAExec remains blocked?
If the problem persists after creating an exclusion, perform the following checks.
- Confirm that the policy containing the exclusion is properly applied to the workstation.
- Verify the exact path of the detected file.
- Check the type of exclusion selected: File, Process, File Hash, or other.
- Verify the syntax of the path and wildcards.
- Identify the module that caused the new block.
- Verify whether the exclusion actually applies to this module.
- Compare the timestamps of the Bitdefender and Medulla events.
- Check whether the block involves a different file or process.
Example
Detected file:
C:\Windows\PAExec-2124-CSE-SDN-ALV-02.exe
Exclusion pattern to check:
C:\Windows\PAExec-*.exe
If the rule is applied correctly but the block persists, the issue may stem from a protection module other than the one initially identified.
Caution:
Do not automatically extend the exclusion to all modules.
First analyze the new detection and verify the scope of the proposed changes.
25. How do I handle a Bitdefender false positive?
Bitdefender has an official procedure for handling legitimate applications that are detected as threats.
When a Medulla operation is blocked:
- Save the detection information.
- Verify that the file in question is indeed from your Medulla installation.
- Check its SHA256 hash.
- Verify that the Medulla operation matches the Bitdefender event.
- Test a targeted exclusion if warranted.
- If the problem persists, submit the necessary information to Bitdefender Support for analysis.
The official Bitdefender documentation also describes how to collect and submit samples when a legitimate application is incorrectly detected.
Bitdefender documentation:
Resolving legitimate applications detected as threats by Bitdefender
26. Can Bitdefender be temporarily disabled to perform a diagnostic check?
Bitdefender documents a diagnostic procedure that involves cloning a policy and temporarily disabling On-access protection on a specific workstation.
However, this operation reduces the workstation’s level of protection and should not be used as a standard method for resolving PAExec issues.
It should be reserved for diagnostic actions expressly authorized by the security team.
First, try the following:
- Analyzing GravityZone events.
- Verifying paths and hashes.
- Creating a targeted exclusion.
- Reviewing Medulla logs.
- Contact Bitdefender support.
Important:
Do not permanently disable Bitdefender protection to allow Medulla to function.
27. How do I remove an exclusion that is no longer needed?
When an exclusion is no longer needed, it must be removed from the corresponding policy or exclusion list.
General procedure
- Log in to GravityZone Control Center.
- Open the relevant policy or configuration profile.
- Go to the list of exclusions.
- Identify the rule to be removed.
- Check the policies and workstations that use it.
- Delete the rule or remove its association with the relevant list.
- Save the changes.
- Verify that the changes have been applied to the workstations.
Then run a Medulla test to confirm that the compatibility issue no longer occurs.
Best practice:
Keep a history of exclusions that have been created, modified, or deleted, along with their justification and approval date.
28. What information should you provide to support if a problem arises?
To facilitate troubleshooting, gather the following information:
Medulla information
- Medulla server version.
- Windows agent version.
- Affected feature: deployment, script, Kiosk, or other.
- Date and time of the operation.
- Error message and result of the action.
Windows information
- Windows version.
- Name of the affected workstation.
- Path to the detected PAExec file.
- Relevant Windows events.
- SHA256 hash of the source binary.
Bitdefender information
- Bitdefender Endpoint Security Tools version.
- GravityZone version or environment.
- Applied security policy.
- Module that triggered the block.
- Exact name of the detection.
- Action taken: block, quarantine, or other.
- Any configured exclusions.
Recommendation:
A screenshot or export of the Bitdefender event, combined with the Medulla action history, is generally a useful starting point for diagnosis.
29. Security best practices
To maintain a high level of protection while ensuring compatibility with Medulla, we recommend:
- Verify each detection before classifying it as a false positive.
- Prioritize exclusions targeted at a specific file or known hash.
- Limit exclusions to only the affected modules.
- Test the changes on a limited number of workstations.
- Keep the Bitdefender protections not affected by the issue.
- Do not globally exclude the Windows directory.
- Do not disable behavioral detection mechanisms across the board.
- Verify the hashes after a Medulla agent update.
- Document exclusions and their rationale.
- Regularly reassess existing exclusions.
- Remove exclusions that are no longer necessary.
- Monitor PsExec and PAExec executions outside of authorized Medulla operations.
30. Summary of technical elements
| Element | Value |
|---|---|
| Security solution | Bitdefender GravityZone / BEST |
| Medulla component | PAExec |
| Source binary | C:\Program Files\Medulla\bin\paexec.exe |
| Possible temporary copy | C:\Windows\PAExec-<PID>-<ComputerName>.exe |
| Path pattern to investigate | C:\Windows\PAExec-*.exe |
| Possible execution account | NT AUTHORITY\SYSTEM |
| Service argument | -service |
| Affected Medulla component | scheduling_launch_kiosk.py |
| Documented exclusion types | File, Folder, Process, File Hash, Certificate Hash, Threat Name, Command Line |
| Supported hash algorithm | SHA256 |
| Wildcards | *, ?, **, according to documented path rules |
| Modules to be examined | On-access, On-demand, ATC/IDS, and other modules specified in the detection |
| Exclusion not recommended | C:\Windows\ as a whole |
31. What procedure should be followed first?
If Bitdefender blocks PAExec, we recommend the following procedure.
Step 1 – Identify the detection
Check the GravityZone events and identify the affected file, module, and security action.
Step 2 – Verify the source of the execution
Confirm that the operation corresponds to an authorized Medulla action.
Step 3 – Verify the binary
Check its path and, if necessary, its SHA256 hash.
Step 4 – Choose a targeted exclusion
Depending on the identified issue, consider an exclusion such as:
- File for a specific path.
- File Hash for a binary identified by its hash.
- File with a wildcard for a temporary copy with a dynamic name, only after a risk assessment.
- Another type of exclusion when warranted by the responsible module.
Step 5 – Test on a pilot workstation
Apply the policy only to the affected workstation and rerun the Medulla operation.
Step 6 – Verify the result
Check the Medulla and GravityZone logs.
Step 7 – Deploy gradually
If the tests are successful and the exclusion is approved by the security team, gradually roll out the policy to the affected workstations.
In summary:
Compatibility between Medulla and Bitdefender GravityZone must be addressed by precisely identifying the module responsible for the block.
GravityZone offers several exclusion mechanisms that allow you to tailor the security policy.
The goal is to restore authorized Medulla operations without creating excessively broad exclusions.
32. Sources and official documentation
Information regarding the configuration of GravityZone exclusions comes from the official Bitdefender documentation.
Managing GravityZone exclusions
Bitdefender GravityZone – Exclusions
Reference documentation for:
- Creating exclusion lists.
- The different types of exclusions.
- Paths and wildcards.
- System variables.
- SHA256 exclusions.
- Selecting protection modules.
Exclusions built into policies
Bitdefender GravityZone – In-policy exclusions
Documentation regarding exclusions configured directly within security policies.
Antimalware configuration
Bitdefender GravityZone – Antimalware
Documentation on configuring antivirus modules and assigning policies.
On-access protection
Bitdefender GravityZone – On-access
Documentation regarding the scanning of files when they are accessed or executed.
False positive management
Bitdefender – Resolving legitimate applications detected as threats
Official procedure for handling legitimate applications detected as threats.
Creating and managing policies
Bitdefender GravityZone – Creating policies
Documentation regarding policies and configuration profiles.
Note:
The PAExec mechanisms described in this FAQ correspond to the functionality presented for Medulla.
The procedures for creating exclusions, the types of exclusions, wildcards, and protection modules are taken from the Bitdefender documentation.
The suggested PAExec paths have been adapted to the Medulla context. Their validity must be confirmed based on events actually observed on the affected workstations.