Skip to main content

Adapting a shipped probe

The 24 probes shipped with Medulla cannot be edited. On their rows, the edit icon is greyed out, and this is deliberate: they are updated with the product, and a local change would be overwritten by the next version.

You still have two ways to adapt them.

Changing a threshold, without duplicating

If you only want a different threshold — alerting at 75 % rather than 85 % — leave the probe alone: use the settings per entity of the probe sheet, described in the previous chapter. You keep the original probe, its updates and its name, with your own thresholds.

This is the most common case, and the simplest.

Duplicating, for everything else

Changing the command, adding a condition, editing the message: for that, you need a copy. The Duplicate action of the row or of the sheet creates a variant that belongs to you and that you can edit freely.

The dialog box asks for two things:

  • the label of the copy, prefilled with the original name followed by (copy)
  • the entity the copy will belong to

Three points to remember:

Conditions are copied. The variant starts with the same thresholds, severities and messages as the original. You only have to change what differs.

Assignments are not. The copy measures nothing until you have assigned it. This is intended: duplicating a probe assigned to the whole fleet must not double the load on the fleet by accident.

The copy belongs to you. It is visible to the users of your entity if its visibility is Shared, to you alone if it is Private. It never reaches another entity.

Once the copy is created, you edit it like a personal probe, with the same form — command, condition, options.

Changing the visibility

The Change visibility action of a probe that belongs to you switches between Shared, visible to your entity, and Private, visible to you alone.

A shared probe remains usable by your colleagues of the same entity; switching to private takes nothing away from what they have already assigned, but the probe disappears from their catalog.

Deleting a probe

The trash icon deletes a probe that belongs to you — it is greyed out on shipped probes, which cannot be deleted.

Warning: deleting a probe removes its assignments, stops the measures on the machines concerned and closes the open alerts. Its past measures disappear with it: the curves cannot be rebuilt.

If you only want to stop measuring, remove its assignments rather than the probe. You will keep the history and can assign it again later.